MENU
  • Home
    • About Us
    • Contact Us
    • Blog >
      • Technical Bulletin
    • Engineering Projects >
      • Diesel Power Station Extension, Gove NT
      • Condamine Power Station, QLD
      • West Kimberley Power Project
      • Millennium Arts Project, Southbank
      • Andoom Power Station, Weipa QLD
  • Engineering
    • RPEQ
    • Power Generation >
      • Air-J1939
      • Air-EMCP
      • Powertrain Generator System
      • Remote Area Power Stations
      • Power Generation Systems
      • Type B Appliance
    • Electrical Engineering >
      • Power System Studies
      • FEED Studies
      • Cable Systems
      • Underground Transmission Lines
      • Substations
      • Panel Assembly
      • EEHA
    • DETAILED DESIGN & DRAFTING >
      • LNG Plants - Electrical Design
      • Switchgear Assemblies
      • Cable Installation Systems
      • System Automation
      • Substation Switch-Rooms
      • Electrical Drafting
  • Martechnic - Fuel, Lube & Hydraulic Oil Management
    • PORTABLE TEST EQUIPMENT >
      • KITS FOR HIRE
      • TWIN CHECK
      • WIO CHECK Water in Oil
      • MT TEST KIT VERIFIER
      • COMPATIBILITY & DENSITY CHECK
      • IRON CHECK
      • SPOT CHECK
      • VISCOSITY (GO / NO GO)
      • VISCO DENS PLUS
      • VISCO CYLINDER Standard / Low Viscosity
      • JUNG CHECK - Viscosity
      • AN (Acid Number) CHECK
      • SALT CHECK
      • SAMPLING KIT
      • INSOLUBLE-CHECK
      • FLASH POINT CHECK
    • TEST KITS >
      • ALWAVIS CHECK
      • LUBE OIL CHECK 5
      • LUBE OIL CHECK 6
      • LUBE OIL CHECK OS
      • FUEL & LUBE OIL TEST CABINET
    • SAMPLING >
      • DRIP SAMPLER PRESSURE-PLUS
      • SAMPLING BOTTLES
      • MT SAMPLE RETENTION SYSTEM
      • DRIP SAMPLER
    • STATIONARY SENSORS >
      • MT MODULAR MONITORING SYSTEM
      • AHHOI + MANIFOLD
      • AHHOI IR WATER IN-LINE
      • PARTICLE SENSOR
      • VISCOSITY SENSOR
      • HUMIDITY SENSOR STANDARD
      • HUMIDITY SENSOR PLUS
      • FE SENSOR
      • DATALOGGER
    • CLEANING >
      • ULTRASONIC CLEANING TANK
      • ULTRASONIC GENERATOR
      • ULTRASONIC CLEANING LIQUID

Electronic Circuit Signal Line Protectors

Signal Line Surge Protectors
The LDU Gatekeeper GKSLP1 range is a high quality, low cost DIN compliant signal line protector of a modular design. Therefore when the device expires, you simply replace the module to reinstate the protector to full capacity.
The protector has been designed to protect sensitive electronic circuits and components from damaging over voltages and currents.  Voltage Ranges: 5, 12, 24, 48, 64, 130.
Click Here to Request a Project Quote
Electronic Signal Line & Data Protectors Product Range
Please visit the Store to purchase online.
SIGNAL LINE PROTECTORS, Complete Protectors
  • GKSLP1-2-5: Single Pair  2A 5V 2Mbps 10KA
  • GKSLP1-2-12: Single Pair 2A 12V 2Mbps 10KA
  • GKSLP1-2-24: Single Pair 2A 24V 2Mbps 10KA - 4-20mA Loop
  • GKSLP1-2-48: Single Pair 2A 48V 2Mbps 10KA - C-BUS
  • GKSLP1-2-68: Single Pair 2A 68V 2Mbps 10KA
  • GKSLP1-2-130: Single Pair 2A 130V 2Mbps 10KA
SIGNAL LINE PROTECTORS, Replacement Modules
  • GKSLP1-2-5/M: Replacement Module 5V
  • GKSLP1-2-12/M: Replacement Module 12V
  • GKSLP1-2-24/M: Replacement Module 24V
  • GKSLP1-2-48/M: Replacement Module 48V
  • GKSLP1-2-68/M: Replacement Module 68V
      Note: RS485 is 12V unit
DATA LINE PROTECTORS
  • RS232 9-9: RS232 9-9 Pin - 9 Pin Protected - DB9 Head shell
  • RS232 25-9: RS232 25-9 Pin - 9 Pin Protected - DB9 Head shell
  • RS232 25-25: RS232 25-25 Pin - 9 Pin Protected - DB25 Head shell
  • RS422 9-9: RS422 9-9 Pin - 9 Pin Protected - DB9 Head shell
  • RS422 25-25: RS422 DB25 Head shell
SIGNAL LINE PROTECTORS, Four Pair
  • DB 4 0.1 06: 6VDC 7.2V Peak 100mA 20kA
  • DB 4 0.1 12: 12VDC 14.4V Peak 100mA 20kA
  • DB 4 0.1 24: 24VDC 28.6V Peak 100mA 20kA - 4-20mA loop
  • DB 4 0.1 48: 48VDC 57.6V Peak 100mA 20kA
  • DB 4 0.5 06: 6VDC 7.2V Peak 500mA 20kA
  • DB 4 0.5 12: 12VDC 14.4V Peak 500mA 20kA
  • DB 4 0.5 24: 24VDC 28.6V Peak 500mA 20kA - 4-20mA loop
  • DB 4 0.5 48: 48VDC 57.6V Peak 500mA 20kA
  • DB 4 5.0 06: 6VDC 7.2V Peak 5A 20kA
  • DB 4 5.0 12: 12VDC 14.4V Peak 5A 20kA
  • DB 4 5.0 24: 24VDC 28.6V Peak 5A 20kA - 4-20mA loop
  • DB 4 5.0 48: 48VDC 57.6V Peak 5A 20kA
Notes:
- RS232 9-9   9 Pin Cannon Connector
- RS232 25-9   25 Pin Cannon Connector
- RS232 25-25   25 Pin Cannon Connector
Picture
Gatekeeper GKSLP1 Signal Line Protector
Picture
Gatekeeper GKSLP1
Picture
Replacement Module
Signal Line Protector - 130V
Picture
Gatekeeper GLSLP1-2-130
Picture
Gatekeeper GKSLP1-2-130 External Earth

GKSLP SIGNAL LINE PROTECTOR

Product Description  
The LDU GKSLP range is a high quality low cost DIN compliant signal line protector of a modular design. Therefore when the device expires, you simply replace the module to reinstate the protector to full capacity. The protector has been designed to protect sensitive electronic circuits and components from damaging over voltages and currents.
Features
•                          Operates directly with DC Supply, RS-232, RS-422, and RS-485 and with 20mA and 50mA
                      instrumentation loops and industrial circuits.
•                    Ideal for high frequency video or telecommunication transmission
•                    Modular in design
•                    Signal transmission is not interrupted when changing the module
•                    Fast acting

Picture
Picture
Installation 
The GKSLP should be connected in series with the DC supply, data communication or signal line as close as possible to the equipment.

GKLSP DC Data Sheet
Picture
Product Description 110V GKSLP
The LDU Gatekeeper SLP range is a high quality low cost signal line protector designed to protect sensitive electronic circuits and components from damaging over voltages and currents.
Features
·                     Designed to operate directly intercom circuits and communication circuits.
·                     Ideal for 110V applications
·                     Fast acting
·                     Screw terminals
Installation  
On the terminal block there are 4 terminals. The label indicates the terminal identification showing 2 lines in and 2 lines out. Therefore 2 terminals are allocated for a single line. The lines from the equipment are terminated into the terminals marked as “IN”. The PE earth wire is to be connected to the equipment frame.
GKSLP 110V Data Sheet
Picture
Batterham's Electrical Switchboard Services & Trading Pty Ltd (BESST Pty Ltd). +61 (0)7 3170 6201 Level 36, Riparian Plaza, 71 Eagle Street, Brisbane. QLD 4000 Australia
  • Home
    • About Us
    • Contact Us
    • Blog >
      • Technical Bulletin
    • Engineering Projects >
      • Diesel Power Station Extension, Gove NT
      • Condamine Power Station, QLD
      • West Kimberley Power Project
      • Millennium Arts Project, Southbank
      • Andoom Power Station, Weipa QLD
  • Engineering
    • RPEQ
    • Power Generation >
      • Air-J1939
      • Air-EMCP
      • Powertrain Generator System
      • Remote Area Power Stations
      • Power Generation Systems
      • Type B Appliance
    • Electrical Engineering >
      • Power System Studies
      • FEED Studies
      • Cable Systems
      • Underground Transmission Lines
      • Substations
      • Panel Assembly
      • EEHA
    • DETAILED DESIGN & DRAFTING >
      • LNG Plants - Electrical Design
      • Switchgear Assemblies
      • Cable Installation Systems
      • System Automation
      • Substation Switch-Rooms
      • Electrical Drafting
  • Martechnic - Fuel, Lube & Hydraulic Oil Management
    • PORTABLE TEST EQUIPMENT >
      • KITS FOR HIRE
      • TWIN CHECK
      • WIO CHECK Water in Oil
      • MT TEST KIT VERIFIER
      • COMPATIBILITY & DENSITY CHECK
      • IRON CHECK
      • SPOT CHECK
      • VISCOSITY (GO / NO GO)
      • VISCO DENS PLUS
      • VISCO CYLINDER Standard / Low Viscosity
      • JUNG CHECK - Viscosity
      • AN (Acid Number) CHECK
      • SALT CHECK
      • SAMPLING KIT
      • INSOLUBLE-CHECK
      • FLASH POINT CHECK
    • TEST KITS >
      • ALWAVIS CHECK
      • LUBE OIL CHECK 5
      • LUBE OIL CHECK 6
      • LUBE OIL CHECK OS
      • FUEL & LUBE OIL TEST CABINET
    • SAMPLING >
      • DRIP SAMPLER PRESSURE-PLUS
      • SAMPLING BOTTLES
      • MT SAMPLE RETENTION SYSTEM
      • DRIP SAMPLER
    • STATIONARY SENSORS >
      • MT MODULAR MONITORING SYSTEM
      • AHHOI + MANIFOLD
      • AHHOI IR WATER IN-LINE
      • PARTICLE SENSOR
      • VISCOSITY SENSOR
      • HUMIDITY SENSOR STANDARD
      • HUMIDITY SENSOR PLUS
      • FE SENSOR
      • DATALOGGER
    • CLEANING >
      • ULTRASONIC CLEANING TANK
      • ULTRASONIC GENERATOR
      • ULTRASONIC CLEANING LIQUID