MP1200 P6
4 digit display in a 48x96 box for 4÷20mA, 0÷20mA, 0÷10V input and thermocouples J, K, S, and Pt100. Optional 3 relay alarm outputs, analogue output and serial outputs.
|
GENERAL DESCRIPTION
The MP1200 P6 model is an instrument with a dual slope converter to interface transducers (2 or 3 wires), thermocouplings and thermoresistors or voltmeter/ammeter amplifiers. The scales available are listed in the "Characteristics" section. The instrument has the following functions: - 4 digit indicator (-1999÷9999) - reading of any input value inside the requested range - zeroing of automatic reading function - reading at 4 conv/sec (no programmed filter) - fixed zero (visualization from -1990 to 9990) - possibility of read out with 20 steps linearization The MP1200 P6 instruments can be ordered with the following options: - Two relay alarm outputs (three if 220V power supply) programmable for value, hysteresis and delay - analogue outputs (4÷20mA or 0÷20mA or 0÷10V) - RS232, RS422 or RS485 serial output Download MP1200 P6 Series User Manual - http://www.mect.it/dati/file/prodotti/81_MP1200%20P6_EN.pdf
|
|
TECHNICAL CHARACTERISTICS
Readings: 4 digits Accuracy better than: 0,5% Thermal stability: 50 ppm/°C Transducer power supply* : 16V/20mA (unregulated) Inputs: tc J, K, S; RTD Pt100; 0÷20mA; 4÷20mA; 0÷10V Analogue outputs features: Outputs: 4÷20mA - 0÷20mA - 0÷10V Max load for current output: 400Ω Min. load for voltage output: 1KΩ Resolution: 12 bit Exchange relay output: 5A / 250Vac Power supply: 90÷260 Vac/Vdc, 25Vac, Vcc o Vpt (12[divid]30Vdc) Power absorption: 1,5 W Max working temperature: 50 °C Digits height: 13mm Dimensions: 48x96 (75 mm. Depth) Mounting plate: 44.5mm (h) x 92.5 mm (l) Weight: 250 gr. Mounting: by bolts * with dc power supply, Val=14Vdc if Vdc power supply >16Vdc |
OPTIONS AND SERIAL OUTPUTS
SR2: 2 relay alarms SR3: 3 relay alarms (only with 220V power supply) OAP: analogue outputs Cod. 2: RS 422 bi-directional Cod. 3: RS 485 bi-directional Cod. 4: RS 232 bi-directional |