MPCT301 P6
6 digit display in a 48x96 box for pulse, RPM, frequency meter, hourly production count and timer. Optional 3 relay alarm outputs and analogue and serial outputs.
|
GENERAL DESCRIPTION
The MPCT301 P6 model is a programmable instrument with uni-directinal pulse counter, rpm meter, frequency meter, hourly production meter or timer. The instrument offers the following functions: - memorized count after power down - 6 digit counters - analogue outputs (4÷20mA, 0÷20mA o 0÷10V) - bi-directional serial outputs with opto isolation (RS485 half duplex) - input from encoders - NPN or PNP sensors or mechanical contact - possibility of "up" or "down" counting - pre-set DOWN counting (counter and timer) - divisor programmable from 1 to 65535 - multiplier programmable from 1 to 65535 - 8 programmable scales in timer mode - in timer mode it is possible to select a stop watch function (hold and reset) or a chronometer (start, stop, reset) - total count functioning - 3 alarm outputs ( 5A relay) - alarms in RPM, frequency meter and hourly production mode: threshold or windows - alarms in counter or timer mode: threshold, threshold with stop counting or automatic cycle Download MPCT301 P6 Series User Manual -
http://www.mect.it/dati/file/prodotti/71_MPCT301%20P6_EN.pdf |
TECHNICAL CHARACTERISTICS
Transducer power supply: 16Vdc / 50 mA unregulated on request 5Vdc 20 mA
Counter max input frequency: 10KHz
RPM max input frequency: 10KHz
Exchange relay output: 5A / 250Vac
Analog outputs: 4÷20mA - 0÷20mA - 0÷10V
Max load for current output: 400Ω
Min. load for voltage output: 1KΩ
Resolution: 12 bit
Power supply: 90÷260 Vac/Vdc, 20÷30 Vac/Vdc
Power absorption: 5 W
Max working temperature: 50 °C
Digits height : 13 mm
Dimensions: 48x96 (75 mm. Depth)
Mounting plate: 44,5 mm (h) x 92,5 mm (l)
Weight: 250 gr.
Mounting: by bolts
OPTIONS AND SERIAL OUTPUTS
SR1÷3: 1÷3 relay alarms
OAP: Analogue outputs (0÷20mA, 4÷20mA, 0÷10V)
V5: Transducer power supply 5Vdc / 20mA
IBT: Magnetic sensor input
Cod. 2: RS 422 bi-directional
Cod. 3: RS 485 bi-directional
Cod. 4: RS 232 bi-directional
Cod. 12: RS 422 optoisolated bi-directional
Cod. 13: RS 485 optoisolated bi-directional
Cod. 14: RS 232 optoisolated bi-directional
Transducer power supply: 16Vdc / 50 mA unregulated on request 5Vdc 20 mA
Counter max input frequency: 10KHz
RPM max input frequency: 10KHz
Exchange relay output: 5A / 250Vac
Analog outputs: 4÷20mA - 0÷20mA - 0÷10V
Max load for current output: 400Ω
Min. load for voltage output: 1KΩ
Resolution: 12 bit
Power supply: 90÷260 Vac/Vdc, 20÷30 Vac/Vdc
Power absorption: 5 W
Max working temperature: 50 °C
Digits height : 13 mm
Dimensions: 48x96 (75 mm. Depth)
Mounting plate: 44,5 mm (h) x 92,5 mm (l)
Weight: 250 gr.
Mounting: by bolts
OPTIONS AND SERIAL OUTPUTS
SR1÷3: 1÷3 relay alarms
OAP: Analogue outputs (0÷20mA, 4÷20mA, 0÷10V)
V5: Transducer power supply 5Vdc / 20mA
IBT: Magnetic sensor input
Cod. 2: RS 422 bi-directional
Cod. 3: RS 485 bi-directional
Cod. 4: RS 232 bi-directional
Cod. 12: RS 422 optoisolated bi-directional
Cod. 13: RS 485 optoisolated bi-directional
Cod. 14: RS 232 optoisolated bi-directional