MPT390 M6
Thermoregulator in a 48x96 box with two display for 4÷20mA, 0÷20mA, 0÷10V, J, K, S, and PT100.
Output PID or ON-OFF control with static or relay output. Ramp control with 3 programs with of 8 steps each. Optional 2 alarm relays output, analogue output and serial outputs.
Output PID or ON-OFF control with static or relay output. Ramp control with 3 programs with of 8 steps each. Optional 2 alarm relays output, analogue output and serial outputs.
GENERAL DESCRIPTION
The MPT390 M6 instrument model is a "single loop" temperature controller in 48x96 container with the possibility to execute 3 programs of 8 steps each and servomotor control drive. The MPT has an interface with thermoresistors, thermocouplings and analog inputs. The management software allows instrument set-up directly from the key-board; the control is by PID/ON-OFF together with "soft-start" function and "self-tuning" for automatic acquisition of the control parameters. The instrument may be ordered with the following options: - Bi-directional serial outputs with or without opto isolation - Tension or current output for motorized valve control or read-out output with or without opto isolation Download MPT390 M6 Series User Manual -
http://www.mect.it/dati/file/prodotti/121_me4014_15_mpt390_m6_a5.pdf |
TECHNICAL CHARACTERISTICS
Thermal stability: 50ppm/°C Accuracy better than: 0.5% Inputs: tcJ, K,S; RTD Pt100; 0÷20mA; 4÷20mA; 0÷10V Controls: PID, ON-OFF Cold junction compensation: automatic Analogue outputs features: Outputs: 4÷20mA - 0÷20mA - 0÷10V(ch1)- 0÷10V(ch2) Max load for current output: 300Ω Min. load for voltage output: 1KΩ Resolution: 12 bit Load. input 4÷20mA: 20Ω Load. input 0÷10V: 1MΩ Heater break: by TA/1A or 1Adc Relay output for alarms: 5A / 250Vac Exchange relay output for main control: 5A / 250 Vac Static output: for solid state relay Power supply: 12÷30Vac/Vdc , 90÷260Vac/Vdc Power absorption: 5W Max working temperature: 50 °C Height digits: 8 mm read out (red) - 8mm set point (green) Dimensions: 48x96 (120mm depth) Mounting plate: 92,5 mm (h) x 44,5 mm (l) |
OPTIONS AND SERIAL OUTPUTS
Position 1: B: Main relay output + static output Psition 2: 01: 2 alarms + heater break 02: 2 alarms 03: 1 alarm Position 3: OAP: Analogue outputs for motor valve control or read-out OAC: Optoisolated analogue outputs for motor valve control or Read-out Cod. 2: RS 422 bi-directional Cod. 3: RS 485 bi-directional Cod. 4: RS 232 bi-directional Cod. 12: RS 422 optoisolated bi-directional Cod. 13: RS 485 optoisolated bi-directional Cod. 14: RS 232 optoisolated bi-directional |